Electrical contractors in Washington
Washington licenses this trade at state level through the Washington State Department of Labor & Industries, so one search covers the whole state. This page holds 9,259 licenses, copied from the L&I file published 2026-10-22. Then say what the job is, and each result says whether the licence reaches it — not just whether it exists.
Built from the Washington State Department of Labor & Industries file published . Every answer here states the date it is speaking from, and L&I's own lookup is where a check is confirmed. Electrical contractors only.
What this file says about itself
Every figure here is as of 2026-10-22, the day L&I published the file — not as of today. That is deliberate: a count of current licenses recomputed on each page view is a different number every day and a wrong one the moment the refresh stops.
- 9,259licenses in the file
- 5,57360% of the file — unexpired, and recorded by L&I as active
- 3,31736% of the file — past their expiry date on that date, of which 734 carry a different L&I word — closed, re-licensed, and so on — which is why this is larger than the EXPIRED row below
- 374still live, but due to expire within the following 90 days
That last figure is the reason a license check has a shelf life. 374 of these licenses lapse within three months of the file’s own date unless they are renewed, and a printout of this page taken today can be wrong about any of them by the time the work starts.
L&I’s own words, and how often each appears
L&I publishes a status word for every license, and this page repeats that word rather than working one out from the expiry date. 337 of these licenses carry a word meaning something is wrong while their expiry date was still ahead — the exact combination a date-only reading calls current, and the exact case someone checking a contractor is checking for. A further 32 are unexpired and not active either, and are deliberately not counted with them: L&I records those as replaced — a business that re-registered, usually after a change of legal entity — which is not a finding against anybody. So subtracting the first two figures above from the total reaches 369 rather than 337, and this is where the difference goes.
| L&I recorded | Licenses | Share |
|---|---|---|
| ACTIVE | 5,573 | 60% |
| EXPIRED | 2,583 | 28% |
| RE-LICENSED | 397 | 4% |
| OUT OF BUSINESS | 392 | 4% |
| SUSPENDED | 288 | 3% |
| PASSED AWAY | 13 | under 1% |
| INACTIVE | 12 | under 1% |
| REVOKED DUE DEPT ERR | 1 | under 1% |
What each specialty is allowed to do
L&I registers every contractor on this page under one license type — electrical contractor — and then records a specialty that limits what its holder may work on. Take the commonest job a homeowner hires an electrician for, a panel or service upgrade on a house: 2,481 of the 9,259 here hold a specialty the rule says does not reach it, and 476 more hold one where the rule does not settle it. That count is by specialty and nothing else — many of them are registered and current, and their status word is the same word a general contractor’s record carries. The status word is not the thing that separates them.
The limits below are read from WAC 296-46B-920, which sets a scope of work for each specialty L&I names in WAC 296-46B-940. Where the rule does not settle a job, the search above says so rather than guessing.
| L&I’s word | What the rule limits it to | Licenses | Share |
|---|---|---|---|
GENERAL | general electrical work, with no scope limit of its own | 5,339 | 58% |
RESIDENTIAL | one- and two-family dwellings, and multifamily up to six stories of type III, IV or V construction | 963 | 10% |
LIMITED ENERGY | low-voltage circuits, plus at most a 120-volt 20-amp connection inside a control cabinet | 878 | 9% |
HVAC/RFRG | HVAC and refrigeration equipment itself — not the line-voltage disconnect outside it | 781 | 8% |
PUMP & IRRIGATION | water pumps and irrigation systems, and the circuits that feed them | 226 | 2% |
MAINTENANCE | maintenance, repair and like-in-kind replacement of existing equipment in non-residential buildings — not homes, and not upgrades | 135 | 1% |
SIGN | signs and outline lighting, and a service of up to 60 amperes to feed them | 132 | 1% |
DOMESTIC PUMP | pumps in residential drinking-water or sewage systems, up to 7½ horsepower at 250 volts single phase, extending a branch circuit that somebody else installed — not installing that circuit | 91 | under 1% |
APPLIANCE REPAIR | a single appliance on its own supply, up to 250 volts and 60 amperes single phase | 74 | under 1% |
RESIDENTIAL MAINTENANCE | maintenance, repair and like-in-kind replacement in homes, up to 250 volts and 60 amperes single phase — not upgrades | 68 | under 1% |
DOORS & GATES SPECIALTY | the wiring of door, gate and similar operators | 41 | under 1% |
HVAC/RFRG-RESTRICTED | HVAC and refrigeration equipment whose primary supply is no more than 250 volts single phase or 120 amps | 31 | under 1% |
LIGHTING MAINTENANCE | work inside the housing of existing non-residential light fittings, including energy-efficiency retrofits | 23 | under 1% |
EQUIPMENT REPAIR | the repair of existing equipment | 11 | under 1% |
RTD NON-RES MAINTENANCE | non-residential maintenance up to 277 volts and 20 amperes on lighting branch circuits, or 250 volts and 60 amperes elsewhere, and never replacing a circuit breaker | 1 | under 1% |
| none recorded | L&I left this column blank, so what the license permits cannot be read off the file at all — ask L&I. | 465 | 5% |
Which licences reach which job
The picker above asks the reader for the job and the results answer it. This is the same answer, worked out from WAC 296-46B-920 for every job on that list, so it can be read without searching — and so the page states it rather than promising it.
| The work | Specialties the rule says reach it | Specialties it says do not | Licences it rules out |
|---|---|---|---|
| A panel or service upgrade on a house | GENERAL, RESIDENTIAL | LIMITED ENERGY, HVAC/RFRG, PUMP & IRRIGATION, MAINTENANCE, SIGN, DOMESTIC PUMP, APPLIANCE REPAIR, RESIDENTIAL MAINTENANCE, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE, RTD NON-RES MAINTENANCE | 2,481 |
| New circuits or rewiring in a house | GENERAL, RESIDENTIAL | LIMITED ENERGY, HVAC/RFRG, PUMP & IRRIGATION, SIGN, DOMESTIC PUMP, APPLIANCE REPAIR, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE | 2,277 |
| Wiring in a commercial or industrial building | GENERAL | RESIDENTIAL, LIMITED ENERGY, HVAC/RFRG, PUMP & IRRIGATION, SIGN, DOMESTIC PUMP, APPLIANCE REPAIR, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE | 3,240 |
| Low voltage only — alarm, network, doorbell, thermostat | GENERAL, RESIDENTIAL, LIMITED ENERGY | HVAC/RFRG, PUMP & IRRIGATION, SIGN, DOMESTIC PUMP, APPLIANCE REPAIR, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE | 1,399 |
| Wiring for heating, air conditioning or refrigeration equipment | GENERAL, HVAC/RFRG | LIMITED ENERGY, PUMP & IRRIGATION, SIGN, DOMESTIC PUMP, DOORS & GATES SPECIALTY, LIGHTING MAINTENANCE | 1,391 |
| A sign or outline lighting | GENERAL, SIGN | RESIDENTIAL, LIMITED ENERGY, HVAC/RFRG, PUMP & IRRIGATION, DOMESTIC PUMP, APPLIANCE REPAIR, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE | 3,108 |
| A water pump or an irrigation system | GENERAL, PUMP & IRRIGATION | RESIDENTIAL, LIMITED ENERGY, HVAC/RFRG, SIGN, APPLIANCE REPAIR, DOORS & GATES SPECIALTY, HVAC/RFRG-RESTRICTED, LIGHTING MAINTENANCE | 2,923 |
A specialty missing from both columns is one WAC 296-46B-920 does not settle for that job, and it is not guessed at here: those licences, together with the 465 the board left blank, are the ones the search returns as ask L&I. The counts are licences on this file, not specialties — a rule that rules out four specialties can rule out very few holders, or most of them.
L&I prints the specialty on its own record for each license, beside a link captioned What can they do?. This page repeats the word and the rule behind it; the board is still where the answer is confirmed. Each share is rounded and the small ones read under 1%, so that column does not add to exactly 100; the counts add to 9,259.
What a result here means
It means the L&I file of 2026-10-22 recorded that license with that status and expiry date. It does not mean the license is current right now: a license can be suspended or revoked between the board’s files, and this copy would not know. That is why every result links to L&I’s own lookup, and why you should use it before hiring anyone.
If a name is not here
A license issued after 2026-10-22 will not be in this copy. L&I registers contractors by license type, and this page covers the electrical contractor type only. A business registered as a construction contractor that also does electrical work is in L&I’s file under that other type, not here.
Washington registers contractors through L&I, and this page covers one license type. A contractor registered under a different type, or under a business name spelled differently from the one you searched, will not appear here even though L&I holds them.
What Washington licenses, and what it does not — and what a license covers, which is less than most people hiring a contractor assume.